- Open the front door. Wait at least 10 minutes for the fuser to cool.
 
- Unlock the fuser by turning the blue thumbscrews counterclockwise.  Using the blue handle, pull out the fuser until it stops.
 
- Press the blue tab to release the safety catch and slide the fuser out until you can place your hand under it for support. 
 
- Remove the fuser.  Push out on the two blue tabs holding the fuser roll to release it.
 
- Lift out the fuser roll and discard it.  Pull the used cleaning pad out of the fuser and discard it.
 
- Place the new fuser roll into the fuser.  Press down firmly on the fuser roll to make sure both ends snap into place.  
 
- Place the new cleaning pad into the fuser
 
- Slide the fuser into the printer, and tighten the blue thumbscrew.  Close the front door.
 
 
HINTS
- Remember that the fuser is heavy and may be hot.
 
- For proper operation, the oiled cloth on the fuser roll must be tight; do not touch it.
 
 
 |  
 
			 | 
	 
 	
 
 |  | 
 
 |